Title: Shear Strength of Post-Tensioned Grouted Keyed Connections
Date: May-June, 1990
Volume: 35
Issue: 3
Page number: 64-73
Author(s): Gangatharan Annamalai
https://doi.org/10.15554/pcij.05011990.64.73

Click here to access the full journal article

Abstract

The shear transfer strength of post-tensioned grouted keyed connections was studied by conducting direct shear tests on shear couplets (push-off tests). The variables studied include different levels of  prestressing and distribution of shear keys along the height of the connection. The shear strength of each connection was evaluated using both the ACI and PCI shear-friction approaches and compared with  experimental results. Based on the experimental investigations, an empirical equation that depends on the grout strength and prestress force across the connection is proposed for evaluating the shear  strength of post-tensioned grouted keyed connections.

References

1. Annamalai, Gangatharan, "Shear Strength of Post-Tensioned Grouted Shear Key Connections," A Dissertation Submitted in Partial Fulfillment of the Degree of Doctor of Philosophy, the University of  Alabama, Tuscaloosa, AL, 1986.

2. Gaston, J. R., and Kriz, L. B., "Connections in Precast Concrete Structures - Scarf Joints," PCI JOURNAL, V. 9, No.3, 1964

3, June 1964, pp. 37-59.3. Hanson, N. W., "Precast Prestressed Concrete Bridges - Horizontal Shear Connections," Journal of the PCA Research  and Development Laboratories,V. 2, May 1960, pp.  35-58.

4. Mattock, A. H., and Hawkins, Neil M., "Shear Transfer in Reinforced Concrete - Recent Research," PCI JOURNAL, V. 17, No. 2, March-Aprill972, pp. 55- 75.

5. ASTM C230, "Flow Table for Use in Test of Hydraulic Cement," ASTM,  Philadelphia, PA, 1983.

6. ASTM A 722, "Uncoated High Strength Steel Bars for Prestressing Concrete,"  ASTM, Philadelphia, P A, 1981.

7. Mast, R. F., "Auxiliary Reinforcement in Concrete Connections," Journal of the Structural Division, ASCE, ST6,  June l968,pp.l485-1503.

8. ACI Committee 318, "Building Code Requirements for Reinforced Concrete  (ACI 318-83)," American Concrete Institute, Detroit, MI, 1983.

9. Rizkalla, Sami H., Serrette, R. L.,Heuvel, J. S., and Attiogbe, E. K., "Multiple Shear Key Connections for  Precast Shear Wall Panels," PCI JOURNAL, V. 34, No. 2, March-April 1989, pp. 104-120 Olesen, S. 0., "Effects of Vertical Keyed Shear Joints on the Design of Reinforced  Concrete Shear Walls," Industrialized Concrete Construction, SP 48, American Concrete Institute, Detroit,MI, 1978.

11. MacLeod, I. A., "Large Panel Structures," Handbook of Concrete Engineering, Edited by Mark Fintel, Van Nostrand Reinhold Company, New York, Second Edition, 1985, pp. 20-39.

12. Foerster, H. R., Rizkalla, S. H., and Heuvel, J. S., "Behavior and Design of  Shear Connections for Loadbearing Wall Panels," PCI JOURNAL, V. 34, No. I, January-February 1989, pp. 102- ll9.

13. Mattock, A. H., "Design Proposals for Reinforced Concrete Corbels," PCI JOURNAL, V. 21, No. 3, May-June 1976, pp. 18-41.

14. ACI Committee 318, "Commentary Building Code Requirements for Reinforced Concrete (ACI 318-83)," American Concrete Institute, Detroit, MI, 1983.

15. PC/ Design Handbook, Third Edition,  Precast/Prestressed Concrete Institute, Chicago, IL, 1985.

16. Moustafa, Saad E., "Effectiveness of Shear-Friction Reinforcement in Shear Diapharagm Capacity of Hollow Core  Slabs," PCI JOURNAL, V. 26, No. 1,January-February 1981, pp. 118-132.